Mounting a Technics EPA 250....

The CW broke part of the plastic damping outer chamber where the cage inserts. I made it worse when I tried to swap one in from a spare parts unit. I need to harden a spring and fabricate a bellows to fix it. It’s pretty low on a very long list.
 
The CW broke part of the plastic damping outer chamber where the cage inserts. I made it worse when I tried to swap one in from a spare parts unit. I need to harden a spring and fabricate a bellows to fix it. It’s pretty low on a very long list.

Yeah there's no shortage of broken stuff around here either. I get that completely.
 
I’d want to get something like my kenwood optical cartridge going first, and I don’t even remember where that is.
 
I’d want to get something like my kenwood optical cartridge going first, and I don’t even remember where that is.

Alright, you got a chuckle out of me. haha

If you have a G you can live without, let me know. I'm not exactly pining for one but I guess I might as well ask.
 
4.5, I think.
I measured tonearm C yesterday.
Can't vouch for accuracy, Fluke 87 V.
Lowest scale nF

Removed head shell
3' of BJC LC1 reportedly ~40 pF, which alone read ~0.04 nF.
With arm bounced 0.06 - 0.07, dwelled on 0.07 nF. Safe to say <0.08 nF w/o head shell leads? So arm ~ 0.3-0.04 nF, 30-40 pF
 
I measured tonearm C yesterday.
Can't vouch for accuracy, Fluke 87 V.
Lowest scale nF

Removed head shell
3' of BJC LC1 reportedly ~40 pF, which alone read ~0.04 nF.
With arm bounced 0.06 - 0.07, dwelled on 0.07 nF. Safe to say <0.08 nF w/o head shell leads? So arm ~ 0.3-0.04 nF, 30-40 pF

Doing the transistor checker hack, I get 18pF for an EPA-100MK2, and 43pF when I hang 1m of LC-1 off it. That'd put my normal setup around 65pF worst-case (8" of my balanced cable equates to about 1M of LC-1), but the cartridge measurements don't bear that out. This is why I want to do it differently, and measure it as a system.
 
I measured tonearm C yesterday.
Can't vouch for accuracy, Fluke 87 V.
Lowest scale nF

Removed head shell
3' of BJC LC1 reportedly ~40 pF, which alone read ~0.04 nF.
With arm bounced 0.06 - 0.07, dwelled on 0.07 nF. Safe to say <0.08 nF w/o head shell leads? So arm ~ 0.3-0.04 nF, 30-40 pF

Also note that if I connect a lead at either end of the DUT I go from 43pF to 60pF.
 
Also note that if I connect a lead at either end of the DUT I go from 43pF to 60pF.
DUT?
So it reads different from each end?
Or both leads at same end ~ 43, a lead at each end ~ 60.
Weird
 
So I did end up with an armwand for the 250. Can anyone tell me what alignment Technics used on this arm? I really want a tool that can show me the correct OEM way to set it up!
 
So I did end up with an armwand for the 250. Can anyone tell me what alignment Technics used on this arm? I really want a tool that can show me the correct OEM way to set it up!
Overhang is 15mm, which should be the standard Technics distance of 52mm from headshell collet to stylus.

I believe Technics uses a modified Stevenson geometry.
 
Back
Top